COMPLEX PLASTICS INC.

 

E-MAIL

Home Page

PRODUCTS  LIST   &  TECHNICAL DATA

 

KAPTON® FN( Polyimide )

REQUEST A QUOTE

films.jpg (8635 bytes)

Designation Construction, mil (µm)
FEP HN FEP
120FN616 0.10 (2.5) 1.00 (25.4) 0.10 (2.5)
120FN616B 0.15 (3.8) 1.00 (25.4) 0.15 (3.8)
150FN019
 
1.00 (25.4) 0.50 (12.7)
200FN919 0.50 (12.7) 1.00 (25.4) 0.50 (12.7)
200FN011
 
1.00 (25.4) 1.00 (25.4)
250FN029
 
2.00 (50.8) 0.50 (12.7)
300FN021
 
2.00 (50.8) 1.00 (25.4)
300FN929 0.50 (12.7) 2.00 (50.8) 0.50 (12.7)
400FN022
 
2.00 (50.8) 2.00 (50.8)
500FN131 1.00 (25.4) 3.00 (76.2) 1.00 (25.4)

Properties of Type FN Film
Heat Seal Strength

Film-to-Film Seals

The peel strength of heat seals between the coated and uncoated sides of one-side coated Kapton® or between the coated sides of both one- and two-side coated Kapton® is determined as follows.

Seals are made in a jaw sealer at 350°C (662°F), 20 psi (1.4 bar), with a 20-sec dwell time. After cooling, the seals are cut into 1. (25.4-mm) wide strips using a Thwing-Albert JDC sample cutter or its equivalent. The seal strength is measured with an Instron-type tensile tester. Seal strength is defined as the peak instantaneous strength occurring in each seal. Five specimen values are averaged.

The minimum peel strength between the coated sides of one- or two-side coated Kapton® film will be 700 g/in (2.7 N/cm), except f120FN616 and 120FN616B, which will be 450 g/in (1.7 N/cm). The minimum peel strength between the coated and uncoated side of one-side coated Kapton® will be 450 g/in (1.7 N/cm).

Film-to-Copper Seals

The ability of FEP film to adhere to copper is measured using the same heat seal peel strength technique as described in "Film-to-Film Seals."

The peel strength is measured with the FEP side sealed to the untreated side of 1 mil (25.4 µm), 3/4 oz GT copper foil; it will be a minimum of 300 g/in (1.2 N/cm).

As-Received Strength (Cold Peel) of Bonds Between Kapton® Type HN and TEFLON® Layers

The bond between the Kapton® Type HN and TEFLON® fluorocarbon resin layers on all Type FN products except 120FN616 and 120FN616B will have a minimum peel strength of 225 g/in (0.87 N/cm), measured using an Instron-type tensile tester and a 180° peel.

* Also applies to Type VN

Dielectric Strength of Kapton® Type FN
Polyimide Films

Gauge Construction

Minimum Breakdown
V/mil (kV/mm)

120FN616
120FN616B
150FN019
200FN919
200FN011
250FN029
300FN021
300FN929
400FN022
500FN131

4,200 (165)
4,200 (165)
3,700 (146)
3,200 (126)
3,200 (126)
2,750 (108)
2,700 (106)
2,700 (106)
2,200 (87)
2,200 (87)

Test Method
Average of ten specimens tested per ASTM D-149-92. Flat sheets in air placed between 1/4" (6 mm) diameter brass electrodes with 1/32" (0.8 mm) edge radius subjected to 60 cycles AC voltage. Rise is 500 V/sec to the breakdown voltage.

Test Method
The percent shrinkage obtained for either the MD or TD by using the average of three measurements in either direction before and after conditioning. Temperature exposure 200°C ± 2°C (392°F ± 3.6°F) f1 hr. Measurements must be made at the same temperature and humidity conditions before and after conditioning. To ensure sample/ambient equilibrium before and after conditioning, specimens should be exposed for 3 hr.

 

Kapton® Polyimide Film Specifications and Tolerances

Film Type Thickness
Nominal
mil (µm)*
Thickness Tolerance Width Range Unit Weight Area Factor
Min.
mil (µm)
Max.
mil (µm)
Min.
in (mm)
Max.
in (mm)
Min.
g/m2
Max.
g/m2
ft2/lb (m2/kg)
120FN616 1.20 (30.5) 1.10 (27.9) 1.40 (35.6) 3/16 (4.8) 44 (1118) 41.0 58.0 104 21.3
120FN616B 1.30 (33.0) 1.20 (30.5) 1.50 (38.1) 3/16 (4.8) 44 (1118) 47.0 54.0 92 18.8
150FN019 1.50 (38.1) 1.25 (31.8) 1.75 (44.5) 3/16 (4.8) 44 (1118) 53.0 74.0 77 15.8
200FN011 2.00 (50.8) 1.70 (43.2) 2.30 (58.4) 3/16 (4.8) 44 (1118) 77.0 104.0 54 11.1
200FN919 2.00 (50.8) 1.70 (43.2) 2.30 (58.4) 3/16 (4.8) 44 (1118) 77.0 104.0 54 11.1
250FN029 2.50 (63.5) 2.25 (57.2) 2.75 (69.9) 3/16 (4.8) 44 (1118) 87.0 113.0 49 10.0
300FN021 3.00 (76.2) 2.60 (66.0) 3.40 (86.4) 3/16 (4.8) 44 (1118) 111.0 142.0 39 8.0
300FN929 3.00 (76.2) 2.60 (66.0) 3.40 (86.4) 3/16 (4.8) 44 (1118) 111.0 142.0 39 8.0
400FN022 4.00 (102) 3.50 (88.9) 4.50 (114) 3/16 (4.8) 44 (1118) 163.0 200.0 27 5.5
500FN131 5.00 (127) 4.50 (114) 5.50 (140) 3/16 (4.8) 44 (1118) 195.0 239.0 23 4.7

*Reference: ASTM D-374-94, Method A, C, or D.  

 WE OFFER 15 FORMULATIONS 

ADDITIONAL INFORMATION

MATERIAL INTRODUCTION


DATA SHEET (click here)

Kapton is a Registered Trademark of the Dupont Company.

E-MAIL

Home Page

PRODUCTS  LIST   &  TECHNICAL DATA

SALES & SERVICE

USA EAST COAST : info@complexplastics.com USA WEST COAST : mike@complexplastics.com

CANADA WEST COAST : bc@complexplastics.com CANADA EAST COAST : sales@complexplastics.com

Europe : europe@complexplastics.com Asia : asia@complexplastics.com     Middle East : MiddleEast@complexplastics.com

Telephone : NORTH AMERICA  1-800-363-2870
Telephone : INTERNATIONAL 001-514-696-6767
            

WAREHOUSES IN MAJOR CITIES

Comments & Suggestions : webmaster@complexplastics.com

 

 

 

 

 

Designed By Weblord Inc, (514) 942-7969 © 1996